NEC Univerge SV8500 Operation And Maintenance Manual page 765

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

In the parameter here, specify the size of increment between the consecutive station numbers to be as-
Note 2:
signed. See the example below:
Example:
INPUT DATA
STN(START)=100
STN(END)=200
STEP=10
TEC:
RSC:
SFC:
Buttons
Execute:
Cancel:
Exit:
Output Data (after Execute button is pressed)
TN:
STN:
LENS:
STATUS:
If OK is not displayed (i.e. the data entry is not successful), related error message is displayed here.
Note:
A Station Number is assigned by increments of 10:
-When asterisk (*) and number (#) are not used as part of STN
100 110 120 130... 190 200
-When asterisk (*) and number (#) are used as part of STN
10* 118 126 134... 1** 1#8
Telephone Equipment Class [1-31]
1=DP (10pps)2=PB
3=DP/PB4=DP (20pps)
5-11=Not used12=Dterm
13=Data Terminal via Dterm14=Hot Line
15=CAS Line16=Data Terminal via Data Module
17=Not used18=Virtual Line Appearance (for Dterm Multi-Line)
19-22=Not used23=ISDN Terminal
24-26=Not used27=8 Conference Equipment
28-31=Not used
Route Restriction Class [0-15]
Service Feature Class [0-15]
Make the input data valid.
Cancel the input data.
Exit this command.
Tenant Number
Assigned Station Number
Line Equipment Number
Data Entry Result
OK=Data Assignment is successful
CHAPTER 7
RESULT
Note
– 718 –
Maintenance Commands

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp85-104 s1e

Table of Contents