SV8500 Server Power ON/OFF Procedure

[AC-Powered Model of SV8500 Server]
Turn ON:
STEP 1: Connect an AC power code to AC inlet on Power module (on the rear panel of
SV8500 server module).
STEP 2: Turn on the PWR switch (to left) (
Turn OFF:
STEP 1: On PCPro Tools menu [System Control], select [System Shutdown] and click the Execute button.
SV8500 server stops operating here.
STEP 2: Turn off the Power switch (to right) on the Power module.
STEP 3: Disconnect the AC power code.
[DC-Powered Model of SV8500 Server]
Turn ON:
STEP 1: Supply the power to BASEU. When the power cable between BASEU and SV8500 server is connect-
ed, BASEU starts supplying the power to SV8500 server here.
STEP 2: Turn on the Power switch (to left) on the Power module (on the rear panel of SV8500 server module)
(
). PWR lamp (on the left of Power switch) lights green.
Note 1
Turn OFF:
STEP 1: On PCPro Tools menu [System Control], select [System Shutdown] and click the Execute button.
SV8500 server stops operating here.
STEP 2: Turn off the Power switch (to right) on the Power module.
STEP 3: Stop supplying the power to BASEU.
When you want to turn on SV8500 server right after turning off the powered system, wait for a while (about
Note 1:
10 seconds) before powering on the system again.
Check the PWR lamp on the front panel of CPU card turns off. When the system is dual configuration, check
Note 2:
the PWR lamp goes off on both #0 and #1 CPU cards.
CHAPTER 5
Operation Procedure for System with PIR
). PWR lamp (on the left of Power switch) lights green.
Note 1
Note 2
Note 2
– 672 –
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp85-104 s1e

Table of Contents