G Bandwidth Warning - NEC Univerge SV8500 Operation And Maintenance Manual

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

36-G: Bandwidth Warning
Default Alarm
NON
This message displays when used bandwidth exceeds the warning value defined between location IDs. Once this
message is displayed, the message has not been output until its recovery. Output of this message can be
controlled by using the office data settings (ABNDL). For more details refer to Office Data Specifications.
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX 0000 0000 3: 0000 0000 0000 0000
2
1
4: 0000 0000 0000 0000 5: 00
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
1
A Location ID
b7
b6 b5 b4
b3
b15 b14 b13 b12 b11
2
B Location ID
b7
b6 b5 b4
b3
b15 b14 b13 b12 b11
Location IDs are set to A LOC-ID and B LOC-ID in ascending order. (A LOC-ID < B LOC-ID)
Note:
Default Grade
3
b0-b15 = A Location ID that exceeded the warning value
b2
b1
b0
b10 b9
b8
b0-b15 = B Location ID that exceeded the warning value
b2
b1
b0
b10 b9
b8
Grade Modified
4
0000 0000 0000 6: 0000 0000 0000 0000
– 504 –
CHAPTER 3
System Messages
Lamp Modified