W Tsw Ready Failure Restore - NEC Univerge SV8500 Operation And Maintenance Manual

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

4-W: TSW Ready Failure Restore
Default Alarm
MN
This message is displayed when TSW Ready failure is restored.
1: XXXX 0XX0 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
1
2
3
4
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
1
Information on TSW Ready failure
restoration
b7
2
Self CPU status after restart
b7
3
Failure information
b7
b3
Default Grade
3
b0:
b1:
b2:
b2
b1
b0
b7:
b0:
b7:
b0
b0–b3: Type of failure (HEX)
b2
b1
b0
Grade Modified
0/1 = -/Failure restoration in TSW system 0
0/1 = -/Failure restoration in TSW system 1
0/1 = Failure restoration in TSW on even-numbered MG/
Failure restoration in TSW on odd-numbered MG
0/1 = TSW in normal state after restart/
TSW in abnormal state after restart
0/1 = -/Monitor restart
0/1 = ACT/STBY
00= -
01= DLKC/PLO initialize failure
02= TSW ACT changeover failure
03= GT card abnormal
04= GT card abnormal (MB control abnormal)
05= TSW ACT changeover failure
06= GT card abnormal
07= GT card abnormal (MB control abnormal)
08= TSW ACT changeover failure
09= During fault processing
0A= During fault processing
0B= TSW ACT changeover failure
– 255 –