NEC Univerge SV8500 Operation And Maintenance Manual page 759

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

If the data for this command is assigned, the node-level data by the ATRF command is not cleared, but
Note:
loses its validity (the network-level data takes precedence).
When time difference exists between the nodes, confirm that the related time difference data, based on
Note 1:
Universal Coordinated Time (UCT) standard, has been assigned at each node via ATDF command.
Assign the traffic measurement time period between Start TIME and End TIME longer than an hour.
Note 2:
Also, if the measurement should be executed throughout a day, assign the same data in both Start TIME
and End TIME parameters.
ATT Answer Peg Count is available for the following Attendant Incoming Calls. Note that the Route
Note 3:
Class Data (CDN 6: TCL) of the Incoming Route must be 1 (=DDD Line)/2 (=FX Line).
Ringdown
LDN Call via ISDN/MFC Line.
Furthermore, there are several conditions described below.
(a) The call terminated to the Attendant on the ground from ISDN trunk when Called Number and Sub
Address cannot be received.
(a) In the case of following Incoming Call from ISDN/MFC line to Attendant Console, these services are
not available.
Call Forwarding-Busy Line/All Calls/Don't Answer to Attendant Console.
Call Forwarding to Attendant Console by Vacant number.
Incoming Call to Attendant Console with All Attendant Access from trunk.
Incoming Call to Attendant Console with Individual Attendant Access.
Incoming Call to Attendant Console with Remote Access to System.
To activate Station Peg Count, ATTCON Peg Count and Service Peg Count, assign the largest value of
Note 4:
Number of Tenants (ASYDN, SYS1, INDEX 8) in all nodes. Assign "FF Hex" for MDATA.
To activate ATTCON Peg Count and ATT Answer Peg Count, assign the largest value of Number of
Note 5:
Attendant Consoles (ASYDN, SYS1, INDEX 9) in all nodes. Assign "FF Hex" for MDATA.
CHAPTER 7
– 712 –
Maintenance Commands

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp85-104 s1e

Table of Contents