NEC Univerge SV8500 Operation And Maintenance Manual page 515

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

Table 3-3 Detailed Fault Information and The Troubleshooting (continued)
4
5
INF ( )
FLT ( )
4A
06
58
80
07
90
C0
C1
D0
08
D1
E0
E1
F0
F1
Detailed Info
7
8
80
23
Failed to negotiate with terminals
43
10
Failed to receive packets
43
11
Failed to send packets
02
04
Failed to initialize PCMCONT-0 device Reset IPELC (IPLC). If the fault
03
04
Failed to initialize PCMCONT-1 device
0C
04
Failed to initialize VC0 device (Sub
PKG#0)
Complete to initialize VC0 device (Sub
PKG#0)
0C
01
Detect VC0 (DSP) WDT (Sub PKG#0)
0D
04
Failed to initialize VC1 device (Sub
PKG#1)
Complete to initialize VC1 device (Sub
PKG#1)
0D
01
Detect VC1 (DSP) WDT (Sub PKG#1)
0E
04
Failed to initialize VC2 device (Sub
PKG#2)
Complete to initialize VC2 device (Sub
PKG#2)
0E
01
Detect VC2 (DSP) WDT (Sub PKG#2)
0F
04
Failed to initialize VC3 device
Complete to initialize VC3 device
0F
01
Detect VC3 (DSP) WDT (Sub PKG#3)
Description
– 468 –
CHAPTER 3
System Messages
Solution
(1) When the fault occurs in all the
terminals accommodated in
IPELC (IPLC), reset the IPELC
(IPLC). If the fault occurs again,
replace the IPELC (IPLC) with a
new one.
(2) When the fault occurs in some
terminals accommodated in
IPELC (IPLC), reset the IPELC
(IPLC). If the fault occurs again,
replace the terminals with new
ones.
None
None
occurs again, replace the IPELC
(IPLC) with a new one.
Reset IPELC (IPLC). If the fault
occurs again, replace the VCT0 PKG
with a new one.
None
Reset IPELC (IPLC). If the fault
occurs again, replace the VCT1 PKG
with a new one.
None
Reset IPELC (IPLC). If the fault
occurs again, replace the VCT2 PKG
with a new one.
None
Reset IPELC (IPLC). If the fault
occurs again, replace the VCT3 PKG
with a new one.
None