Mux Replacement: 4-Img - NEC Univerge SV8500 Operation And Maintenance Manual

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

STEP 15 Turn OFF the MB key on the new MUX card.
M1SY, M2SY and M3SY lamps (TSW card) = lit (green) (depending on the number of PIR)
MUXACT lamp (new MUX card) = remains off
STEP 16 If PLO MB key on the TSW card is set to ON, turn it OFF.
Note:
PLOACT #0 has higher priority than PLOACT #1. Therefore, PLOACT #0 is automatically set as ACT
when the TSW MB key is turned ON/OFF while the PLO MB key of TSW #0 is OFF.
STEP 17 Turn OFF (down) the MBR key on the TSW card.
TSWACT lamp (TSW card) = off
STEP 18 Execute the TSW ACT/STBY changeover by using CMOD command and confirm the new
MUX card is operating normally.
[End]
1.5.2

MUX Replacement: 4-IMG

MUX circuit card is mounted on each PIR. This circuit card is an interface card to accommodate the Line/
Trunk circuits. Replacement procedure of this circuit card is shown below.
[Start]
Proceed to STEP 3 when speech path is in single configuration. In this case, MN alarm is generated.
Note:
STEP 1
Is the circuit card to be replaced in STBY mode?
Check the MUX ACT lamp on the MUX card. When the lamp is off, the card is STBY mode.
YES: Proceed to STEP 3.
NO: Changeover the TSW ACT to STBY mode by using CMOD command, then proceed to STEP 2.
STEP 2
Confirm the TSW ACT has been changed over normally.
After TSW changeover, check the following lamp indications:
<STBY side>
TSW ACT (TSW card) = off
OPE/MB (DLKC card) = off
MUX ACT (MUX card) = off
<ACT side>
TSW ACT (TSW card) = lit (green)
OPE/MB (DLKC card) = lit (green)
MUX ACT (MUX card) = lit (green)
CHAPTER 5
Operation Procedure for System with PIR
– 560 –

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp85-104 s1e

Table of Contents