STEP 8
In PCPro Tools' Patch menu:
1. Select the following:
2. Press "Execute" button.
(2) Use XPAT command to apply uploaded patch files to the Telephony Server.
STEP 1
Start up XPAT command.
STEP 2
Select target Telephony Server side to apply patches using radio buttons in "Mode: ACT/ST-
BY."
STEP 3
Press "Get" button to display "Patch Information List" (list of uploaded patch files).
• When application for all uploaded patch files have been completed:
STEP 4
Press "Check" button to check formats for patch files.
• When all files are in correct format:
• When an incorrect file format exists:
STEP 5
Press "Apply" button.
Message "Do you apply patch?" appears.
Press "OK" to start applying the patch.
• When all patch file application was successful:
• When patch application failed:
Pressing the "OK" button automatically executes readout to update the Patch Information List. When
Note 1:
patch application failed, the first patch file in "Applied Status" column displayed as "Unapplication"
failed to have the patch applied. Contact the patch provider when this problem occurs.
STEP 6
Press "Exit" button to end XPAT command when patch application is complete.
• Operation:
• Install Data Name:
• Patch Selection:
Message "Everything has been applied." appears.
Press "Exit" button to end XPAT command.
"Apply" button becomes active.
Error message is displayed in "Check Result" column of "Patch Information List."
"Apply" button does not become active.
Message "Patch application success. Display information is updated." appears.
Message "Patch application failed. Display information is updated." appears.
Write
Data selected in STEP 3–1
Data Name set in "Install Data Name" box of STEP 5–2
Note 1
– 921 –