NEC Univerge SV8500 Operation And Maintenance Manual page 223

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

CHAPTER 2
Operations of SV8500 Server
[12]: Protocol
0x01/0x02/0x03 = iLP-PM/PROTIMS/SIP
[13]: Total Number of Transmitted Control PKTs
0x10000000 = 10 times
[14]: Number of Retransmitted Control PKTs
0x09000000 = 9 times
[15]: Number of Failed Control PKTs
0x00000000 = None
[16]: Total Number of Received Control PKTs
0x00000000 = None
[17]: Number of Received Abnormal PKTs
0x13000000 = 19 times
[18]: Number of Failed Control PKTs
0x11000000 = 17 times
[19]: Number of Failed Control PKTs
0x00000000 = None
[20]: Number of Retransmission (three times)
Note
[21]: Number of Retransmission (four times or more)
Note
Available for DtermIP (SIP)/Soft Phone (SIP) only.
Note:
The following shows how to count the numbers and the meaning of each protocol.
This example is applied for all the parameters.
0x016A
362 times
6A 01 00 00
Lower
Upper
Converted in decimal