NEC Univerge SV8500 Operation And Maintenance Manual page 133

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

STEP 4
Loosen the left side screw.
STEP 5
Pull the IOC card slowly toward you to remove from the system.
STEP 6
On the new IOC card, set the switches exactly same as those of the old IOC card.
IOC card has S2 switch (4 - DIP switch).
Note:
STEP 7
Turn on MBR key (left side of SW00) on the new IOC card.
Set MBR key upper position (1).
STEP 8
Insert the new IOC card by placing it on the slots of the server, and then securely insert into the
connector provided on the server.
STEP 9
Fasten the IOC card by tightening the two screws.
STEP 10 Insert the cable support bracket.
STEP 11 Connect the IOC cable (SV 4PORT CA-A) to CONN connector again.
STEP 12 Turn off MBR key (left side of SW00) on the IOC card.
Set MBR key down position (0).
STEP 13 Make sure the following.
OPE lamp starts flashing (IOC card is initialized)
If OPE lamp does not start flashing, check the following.
Note:
- IOC card is securely inserted into the main unit?
- The switch setting of the new IOC card is the same as that of old card?
STEP 14 Make sure equipment that is connected to the new card operating normally.
If it is not operating normally, make sure the IOC cable is securely inserted into the system.
Note:
CHAPTER 2
– 86 –
Operations of SV8500 Server