Avaya DEFINITY Server CSI Maintenance Manual page 1410

Table of Contents

Advertisement

Maintenance Objects
Error Log Entries and Test to Clear Values
Table 369. MMI-PT Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
1 (a)
Any
Uplink error from pack
18 (b)
0
Busyout port PCSSpp
130 (c)
Any
Software generated
257 (d)
Any
None
513 (e)
Any
Resource Loopback
Test (#1111)
1025 (f)
Any
Uplink error from pack
3841 -
Any
Uplink error from pack
3844 (g)
1.
Run the short test sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. The customer endpoint connected on a conference sent too many
messages to the VSP-MCU in a specified amount of time. Check the
"status conference" forms to correlate which customer had the problem.
This is a customer endpoint problem and not a VSP-MCU problem.
b. This port has been busied out by the busyout port PCSSpp command.
c. Indicates that the circuit pack has been removed or has been insane for
more than 11 minutes. To clear the error, replace or reseat the circuit pack.
d. This error occurs if the MMI circuit pack detects a DSP Error. Maintenance
software will reset the DSP when this error is received. This error is logged
for all 8 resources connected to this particular DSP. If this DSP continues to
fail sanity, a Minor alarm is raised. Replace the circuit pack.
e. This error occurs when the Resource Looparound Test (#1111) fails. Run
the Long Test Sequence and note the results of Test #1111.
1410
Issue 5 October 2002
Alarm
Associated Test
Any
WNG
WNG
MAJ/
MIN
MIN
On/ Off
Level
Board
Any
test port PCSSpp sh r 1
OFF
release port PCSSpp
ON
ON
ON
test port PCSSpp sh r 3
Test to Clear Value

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents