Avaya DEFINITY Server CSI Maintenance Manual page 1433

Table of Contents

Advertisement

OPS-LINE (DS1 OPS Line)
Table 377. TEST #312 DS1OPS Switchhook Inquiry Test — Continued
Error
Test
Code
Result
PASS
The station hook states in both switch software and DS1 Interface circuit pack
are consistent.
0
NO
The test could not relate the internal ID to the port (no board). This could be
2012
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
555-233-119
Description/ Recommendation
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, dispatch to
check to ensure that there is a valid board inserted.
Continued on next page
Issue 5 October 2002
1433

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents