Terminal Marking; Direction Of Rotation - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Figure 12-7
12.2.10.3

Terminal marking

For terminal designations, the following principle definitions apply to three-phase motors:
Table 12-10
1
x
 
 
 
12.2.10.4

Direction of rotation

The motors are suitable for clockwise and counter-clockwise rotation.
When the line feeder cables are connected in the phase sequence L1, L2, L3 to U, V, W,
the motor rotates clockwise when looking at the drive end of the shaft extension (DE). If
two of the connections are swapped, the resulting direction of rotation is counter-clockwise,
e.g. L1, L2, L3 to V, U, W.
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Fixing in the terminal box
Terminal designations using the example 1U1-1
U
1
-
1
Designation
 
 
 
 
Index showing the pole assignment for pole-changing three-phase motors
(lower number = lower speed)
or, in special cases, for a subdivided winding
x
 
 
 
Phase designation (U, V, W)
 
x
 
 
Index showing winding start (1)
Index showing winding end (2)
Additional indexes if there is more than one connection per winding
 
 
 
x
Additional indices if it is obligatory to connect parallel line feeder cables to sev‐
eral terminals with otherwise identical designations
Additional information on the SIMOGEAR geared motor
12.2 Specific data motor