Performance and operation with reduced clearance distances require verification in the
individual application.
Mounting dimensions
All dimensions are specified in millimeters (inches).
Frame
size
FSA
FSB
FSC
The glanded variant of the converter provides no cable gland when delivered. The dimension data of
1)
glanded variant applies to the converter installed with the optional glanded installation kit.
For FSB (4 kW) and FSC, the depth D includes the depth of the integrated fan.
2)
Drill patterns
Frame
size
FSA
FSB/FSC
Mounting the motor
The SINAMICS G115D wall-mounted converter supports SIMOGEAR geared motors, SIMOTICS
motors, or third-party motors.
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Rated power
Width
W
0.37 kW to 1.5 kW
380 (15.0)
2.2 kW to 3 kW
425 (16.7)
4 kW
425 (16.7)
5.5 kW to 7.5 kW
425 (16.7)
Drilling dimensions - mm (in)
C1
C2
145 (5.7)
364.5 (14.4)
168 (6.6)
410 (16.1)
4.1 Mounting the G115D Wall Mounted drive
Height
Depth
H
D
156 (6.1)
129 (5.1)
180 (7.1)
134 (5.3)
180 (7.1)
169 (6.7)
180 (7.1)
169 (6.7)
Fixings
Ø
5.5 (0.2)
4 × M5 bolts, wash‐
ers, nuts
5.5 (0.2)
Mounting
Additional height
1)
C
Connector variant:
+30 (1.18)
Glanded variant and
2)
Q8/0 variant:
2)
+30 (1.18)
Converter with
24 V PSU: +60 (2.36)
Tightening tor‐
que
2.5 Nm
(22.1 lbf.in)
41