Advanced commissioning
7.17 Setpoints
Parameter
p1070[0...n]
p1071[0...n]
r1073
p1075[0...n]
p1076[0...n]
r1077
260
Description
CI: Main setpoint
CI: Main setpoint scaling
CO: Main setpoint active
CI: Supplementary setpoint
CI: Supplementary setpoint scaling Signal source for scaling the supplementary set‐
CO: Supplementary setpoint effec‐
tive [rpm]
Setting
Signal source for the main setpoint
The factory setting depends on the converter.
With PROFINET interface: [0] 2050[1]
Without PROFINET interface: [0] 755[0]
Signal source for scaling the main setpoint
Factory setting: 1
Displays the active main setpoint
Signal source for the supplementary setpoint
Factory setting: 0
point
Factory setting: 0
Displays the effective supplementary setpoint. The
value shown is the additional setpoint after scaling.
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA