Checking The Tightness Of Fastening Bolts; Replacing The Hose Of The Oil Expansion Unit - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Additional information on the SIMOGEAR geared motor
12.3 Specific data gearbox
12.3.29

Checking the tightness of fastening bolts

Note
Replace damaged headless bolts with new bolts of the same type and strength class.
Switch off the power supply to the drive unit. Check all fastening bolts for tightness using a
torque wrench.
The general tolerance for the tightening torque in Nm is 10 %. The friction coefficient is 0.14 μ.
Table 12-48
Thread size
M4
M5
M6
M8
M10
M12
M16
M20
M24
M30
M36
12.3.30

Replacing the hose of the oil expansion unit

NOTICE
Hose with leaks
The hose of the oil expansion unit is subject to natural wear. The service life depends on the
operating conditions.
Check the hose regularly for tears or leaks.
Renew the hose every 4 years at the latest.
526
Tightening torques for fastening bolts
Tightening torque for strength class
8.8
Nm
3
6
10
25
50
90
210
450
750
1500
2 500
10.9
Nm
4
9
15
35
70
120
295
580
1 000
2 000
3 600
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
12.9
Nm
5
10
18
41
85
145
355
690
1200
2 400
4 200

Advertisement

Table of Contents
loading

Table of Contents