Wiring
5.11 Connecting the 24 V power supply
7/8" connector
X01 - 24 V power supply
(IN), 5-pin, male
M12 L-coding connector
X01 - 24 V power supply
(IN), 5-pin, male
Glanded variant
X01/X02 - 24 V power supply terminals
Motor-mounted converter
Switched/unswitched 24 V power supply
The unswitched (also known as "non-switched") 24 V power supply (1L+) is required for the drive
to function.
• Use a power supply with PELV (Protective Extra Low Voltage).
• The 0 V of the power supply must be connected with low resistance to the PE of the system.
The switched 24 V (2L+) supplies the two bidirectional digital inputs/outputs DIO 24 and DIO
25. Switching off the 24 V power supply voltage brings all of the actuators connected to the
digital outputs into the no-voltage state.
If you don't need the switching of 2L+ power supply, you can connect the conductors 2M
(switched 0 V) to 1M (unswitched 0 V) and 2L+ (switched 24 V) to 1L+ (unswitched 24 V)
78
X02 - 24 V power supply
(OUT), 5-pin, female
X02 - 24 V power supply
(OUT), 5-pin, female
Wall-mounted converter
 
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Pin
Signal
Description
1
2M
Switched 0 V
2
1M
Unswitched 0 V
3
FE
Not connected
4
1L+
Unswitched 24 V
5
2L+
Switched 24 V
Pin
Signal
Description
1
1L+
Unswitched 24 V
2
2M
Switched 0 V
3
1M
Unswitched 0 V
4
2L+
Switched 24 V
-
FE
Not connected
Signal
2L+
2M
1L+
1M
Cable gland size: M20 * 1.5
SINAMICS G115D Wall Mounted distributed drive
Description
Switched 24 V
Switched 0 V
Unswitched 24 V
Unswitched 0 V