Advanced commissioning
7.5 Drive control via PROFINET
No.
06 hex
07 hex
0B hex
0C hex
11 hex
14 hex
65 hex
66 hex
68 hex
6A hex
6B hex
86 hex
87 hex
C8 hex
C9 hex
CC hex
PNU (parameter number) and page index
The parameter number is located in value PNU in the 1st word of the parameter channel (PKE).
The page index is located in the 2nd word of the parameter channel (IND bit 7 ... 0).
Parameter number
0000 ... 1999
2000 ... 3999
6000 ... 7999
8000 ... 9999
10000 ... 11999
20000 ... 21999
30000 ... 31999
60000 ... 61999
Subindex
For indexed parameters, the parameter index is located in subindex (IND Bit 15 ... 8) as
hexadecimal value.
152
Description
Setting not permitted, only resetting (change request with a value not equal to 0 without
permission)
Descriptive element cannot be changed (change request to a descriptive element error
value that cannot be changed)
No master control (change request but with no master control, see also p0927.)
Keyword missing
Request cannot be executed due to the operating state (access is not possible for tempo‐
rary reasons that are not specified)
Inadmissible value (change request with a value that is within the limits but which is illegal
for other permanent reasons, i.e. a parameter with defined individual values)
Parameter number is currently deactivated (depending on the mode of the converter)
Channel width is insufficient (communication channel is too small for response)
Illegal parameter value (parameter can only assume certain values)
Request not included / task is not supported (the valid request identifications can be found
in table "Request identifications controller → converter")
No change access for a controller that is enabled. (The operating state of the converter
prevents a parameter change)
Write access only for commissioning (p0010 = 15) (operating state of the converter pre‐
vents a parameter change)
Know-how protection active, access locked
Change request below the currently valid limit (change request to a value that lies within
the "absolute" limits, but is however below the currently valid lower limit)
Change request above the currently valid limit (example: a parameter value is too large for
the converter power)
Change request not permitted (change is not permitted as the access code is not available)
PNU
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
0000 ... 1999
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Page index
0 hex
80 hex
90 hex
20 hex
A0 hex
50 hex
F0 hex
74 hex