Conveyor, Two Directions And One Speed (P3393 = 3) - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Advanced commissioning
7.9 Conveyor technology control functions (for G115D PROFINET and AS-i variants only)
Parameters
7.9.1.3

Conveyor, two directions and one speed (p3393 = 3)

Overview
With p3393 (conveyor technology application) set to 3, the converter enables the load on a
conveyor belt to move in either positive or negative direction with a fixed speed. Two sensors are
required to signal the limit positions for the motor to stop.
Precondition
You interconnect the signals of the sensors with the digital inputs of your choice.
190
Conveyor technology control parameters (Page 220)
SINAMICS G115D Wall Mounted distributed drive