Two-Wire Control, Method 1 - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Three-wire control, method 2
Enable/OFF1:
Enables the motor to be switched on
or switched off
ON:
Switches on the motor
Reversing:
Reverses the motor direction of rota‐
tion
7.4.1

Two-wire control, method 1

Command "ON/OFF1" switches the motor on and off. The "Reversing" command inverts the
motor direction of rotation.
Parameters
Select two-wire control, method 1
Parameter
p0015 = 60
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
7.4 Controlling clockwise and counter-clockwise rotation via digital inputs
ON/OFF1
Reversing
0
0
0
1
1
0
1
1
Description
Macro drive unit
You must carry out quick commissioning in order to set parameter p0015.
Assigning digital inputs DI to the commands:
DI 0: ON/OFF1
DI 1: Reversing
Function
OFF1: The motor stops
ON: Clockwise motor rotation
ON: Counter-clockwise motor rotation
Advanced commissioning
137