• Have the bus interface and IP address been correctly set?
• Have the signals that the converter and the control system exchange been correctly
interconnected?
5.14

Connecting to AS-i

5.14.1

General information

General information
The converter operates based on the extended AS-i specification V3.0.
The signaling is made as Manchester-coded current pulses superimposed on the 28 V supply.
Since the power supply is used for communications, it must be decoupled with inductors in
order for the receiver to be able to decode the transmitted messages.
The yellow cable is the communication cable and provides the power to the converter and its
digital inputs. The black cable is the auxiliary power supply cable and provides power to the
digital outputs and the low voltage components of the converter including the fan.
The converter supports Single Slave and Dual Slave modes.
In Single Slave mode, the converter has an address in the AS-i network over which four bits
are transferred. In Dual Slave mode, each converter has two AS-i addresses over each of
which four bits are transferred.
In Single Slave mode, communication is realized in accordance with profile 7.F.E. In Dual
Slave mode, communication is realized in accordance with profiles 7.A.5 and 7.A.E.
Interface settings for commissioning
To configure the communication of the converter via AS-i, the following possibilities are
available for commissioning the converter:
p0015=
30
31
66
34
For details about the interface settings, refer to the following chapter:
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Designation
Macro 30 - AS-i Single Slave with fixed
setpoint
Macro 31 - AS-i Dual Slave with fixed set‐
point
Macro 66 - AS-i Single Slave with set‐
point from Potentiometer 1 or Potenti‐
ometer 2
Macro 34 - AS-i Dual Slave with fieldbus
setpoint
Factory interface setting (Page 82)
5.14 Connecting to AS-i
Meaning
Single Slave mode with specification of a fixed fre‐
quency via the control
Dual Slave mode with specification of a fixed fre‐
quency via the control
Single Slave mode with setpoint from Potentiome‐
ter 1 or Potentiometer 2
Dual Slave mode with "ON/OFF1", "OFF2", speed
setpoint via control
Wiring
95