The Electronic Module is available in PROFINET variant, AS-i variant, and I/O Control (without
fieldbus communication) variant. The Wiring Module is available in glanded variant and
connector variant.
Depending on the variant ordered, the converter is equipped with plug-in sockets and/or
blanking caps (for wiring with cable glands).
For the connector variant, the converter is all wired up internally when delivered and all that
is required is the external wiring of the system. For the glanded variant, make sure you wire
the terminals and route the cables inside the Wiring Module and fix with the cable glands.
Note that the converters of glanded variant provide no cable glands but blanking caps at
delivery for all glanded interfaces.
Wall-mounted converter
The figure below shows an example of PROFINET variant of the wall-mounted converter with
plug-in sockets:
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
5.7 Overview of the converter interfaces
Wiring
61