Figure 12-30
Procedure
1. Assemble the mounting kit 
2. Screw on the tank with the screwed connection 
housing or of the motor bearing shield.
3. Align the oil expansion unit so that it is vertical.
Oil expansion unit size 109
NOTICE
Leaky hose
The hose of the oil expansion unit is subject to a natural aging process.
Check the hose for tears or leaks.
Never commission a leaky hose. Replace the hose.
The hose of the oil expansion unit is not suitable for ambient temperatures below ‑25 °C.
If the ambient temperatures differ, contact Technical Support.
The unit is supplied as a mounting kit.
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
5
Pressure relief valve
Tank
Screwed joint
Mounting an oil expansion unit size 39 - 89
Additional information on the SIMOGEAR geared motor
Tube bend
Screwed connection
 
 
 - 
.
12.3 Specific data gearbox
at the uppermost hole of the gearbox