Parameters
Parameters of the alarm buffer and the alarm history
Parameter
p2111
r2122[0 ... 63]
r2123[0 ... 63]
r2124[0 ... 63]
r2125[0 ... 63]
r2132
r2134[0 ... 63]
r2145[0 ... 63]
r2146[0 ... 63]
Extended settings for alarms
Parameter
You can change up to 20 different alarms into faults or suppress alarms:
p2118[0 ... 19]
p2119[0 ... 19]
For more information about this function, see function diagram 8075 and parameter
description in the List Manual.
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Description
Alarm counter
Alarm code
Alarm time received in milli‐
seconds
Alarm value
Alarm time removed in milli‐
seconds
CO: Actual alarm code
Alarm value for float values
Alarm time received in days
Alarm time removed in days
Description
Changing message type, mes‐
sage number
Changing message type, type Sets the message type for the selected fault or
Alarms, faults and system messages
9.4 Alarms, alarm buffer, and alarm history
Setting
Number of alarms that have occurred after the last
reset.
When setting p2111 = 0, the following is initiated:
All of the alarms that have been removed from
the alarm buffer [0...7] are transferred into the
alarm history [8...63].
The alarm buffer [0...7] is deleted.
Factory setting: 0
Displays the numbers of the alarms that have oc‐
curred.
Displays the time in milliseconds when the alarm
occurred.
Displays additional information about the alarm.
Displays the time in milliseconds when the alarm
was removed.
Displays the code of the alarm that last occurred.
Displays additional information about the alarm
that occurred for float values.
Displays the time in days when the alarm occurred.
Displays the time in days when the alarm was re‐
moved.
Setting
Selects faults or alarms for which the message type
should be changed.
Factory setting: 0
alarm.
1: Fault
2: Alarm
3: No message
Factory setting: 1
377