Wiring
5.2 Permissible line supplies
3. If you are using a wall-mounted converter, in addition to removing the screw from the
Electronic Module as above, remove the grounding screw and the grounding cable from the
Wiring Module.
– For the wall-mounted converter FSA/FSB, first release the four retaining screws to remove
– For the wall-mounted converter FSC, in addition to removing the screw from the Wiring
4. Re-attach the Electronic Module with a tightening torque of 2.5 Nm (22.1 lbf.in).
You have removed the functional grounding from the converter.
56
the blanking cover or the local/remote control (LRC) panel from the Wiring Module (
Then remove the functional grounding screw marked with the
that, re-attach the blanking cover or the LRC panel with a tightening torque of 2.2 Nm
③④
(19.5 lbf.in) (
) to make sure that the converter and the motor can work properly.
Module, also remove the functional grounding cable from the Wiring Module (
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
).
symbol (
). After
⑤⑥
).