Siemens SINAMICS G115D Operating Instructions Manual page 283

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

PID technology controller, fixed values (direct selection)
Parameter
p2216[0...n]
p2220[0...n]
...
p2223[0...n]
r2224
r2225.0
r2229
PID technology controller, motorized potentiometer
Parameter
r2231
p2235[0...n]
p2236[0...n]
p2237[0...n]
p2238[0...n]
p2240[0...n]
r2245
p2247[0...n]
p2248[0...n]
r2250
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Description
Technology controller fixed value
selection method
BI: Technology controller fixed val‐
ue selection bit 0 ... 3
CO: Technology controller fixed val‐
ue active [%]
CO/BO: Technology controller fixed
value selection status word [%]
Technology controller number ac‐
tual
Description
Technology controller motorized
potentiometer setpoint memory
[%]
BI: Technology controller motor‐
ized potentiometer, setpoint, raise
BI: Technology controller motor‐
ized potentiometer, setpoint, lower
Technology controller motorized
potentiometer maximum value [%]
Technology controller motorized
potentiometer minimum value [%]
Technology controller motorized
potentiometer start value [%]
CO: Technology controller motor‐
ized potentiometer, setpoint be‐
fore RFG [%]
Technology controller motorized
potentiometer ramp-up time [s]
Technology controller motorized
potentiometer ramp-down time [s]
CO: Technology controller motor‐
ized potentiometer, setpoint after
RFG [%]
Advanced commissioning
7.19 PID technology controller
Setting
Sets the method to select the fixed setpoints:
1: Direct selection (factory setting)
2: Binary selection
Sets the signal source to select a fixed value of the
technology controller.
Factory setting: 0
Display and connector output for the selected and
active fixed value of the technology controller.
Display and BICO output for the status word of the
fixed value selection of the technology controller.
Displays the number of the selected fixed setpoint
of the technology controller.
Setting
Displays the setpoint memory for the motorized
potentiometer of the technology controller.
Sets the signal source to continually increase the
setpoint for the motorized potentiometer of the
technology controller.
Factory setting: 0
Sets the signal source to continually reduce the set‐
point for the motorized potentiometer of the tech‐
nology controller.
Factory setting: 0
Sets the maximum value for the motorized poten‐
tiometer of the technology controller.
Factory setting: 100
Sets the minimum value for the motorized potenti‐
ometer of the technology controller.
Factory setting: -100
Sets the starting value for the motorized potenti‐
ometer of the technology controller.
Factory setting: 0
Displays the effective setpoint in front of the inter‐
nal motorized potentiometer ramp-function gener‐
ator of the technology controller.
Sets the ramp-up time and ramp-down time for the
internal ramp-function generator for the motorized
potentiometer of the technology controller.
Factory setting: 10
Displays the effective setpoint after the internal
ramp-function generator for the motorized poten‐
tiometer of the technology controller.
281

Advertisement

Table of Contents
loading

Table of Contents