Conveyor Technology Control Parameters - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Advanced commissioning
7.9 Conveyor technology control functions (for G115D PROFINET and AS-i variants only)
Parameters
7.9.5

Conveyor technology control parameters

Parameter
r0722.0...25
p1070[0...n]
p1071[0...n]
p1075[0...n]
220
Conveyor technology control parameters (Page 220)
Description
CO/BO: Digital inputs status
CI: Main setpoint
CI: Main setpoint scaling
CI: Supplementary setpoint
Setting
Interconnect the signals of the sensors to the digi‐
tal inputs as desired.
Sets the signal source for the main setpoint.
Sets the signal source for scaling the main setpoint.
Factory setting: 1
Sets the signal source for the supplementary set‐
point. Note that the supplementary setpoint adds
to both p3397 and p3398
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA