Data backup and series commissioning
8.1 Transferring settings using a memory card
You can transfer parameter settings from the converter to the memory card by the following
methods:
• Automatic transfer
• Transfer with Startdrive
• Transfer with SINAMICS G120 Smart Access
Automatic transfer
Precondition
The converter power supply has been switched off.
Procedure
1. Insert an empty memory card into the memory card slot.
Note
Accidental firmware update
If the memory card contains a converter firmware, the converter may perform a firmware
update after the supply voltage has been switched on.
Note
Accidental overwrite of the converter settings
When the supply voltage is switched on, the converter automatically accepts the settings
already backed up on the memory card. If you use a memory card on which settings are
already backed up, you will overwrite the settings of the converter.
• Use an empty memory card for the first automatic back-up of your settings.
2. Switch on the converter power supply.
After the converter power supply has been switched on, it copies all modified parameters to
the memory card.
Transferring using Startdrive
Precondition
• A memory card is inserted in the converter.
• Connection between the PG/PC and converter has been properly established via a USB cable
or the fieldbus.
• You have installed the Startdrive commissioning tool on your PG/PC.