Siemens SINAMICS G115D Operating Instructions Manual page 116

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Commissioning
6.4 Quick commissioning
Note
Reattach the screws with a tightening torque of 2.5 Nm (22.1 lbf.in).
Function description
You can use the DIP switches to perform basic commissioning and functional settings without
using additional commissioning tools.
When the DIP switches are in the OFF position (by default), the value of the function is
defined by the value of the according parameter(s) (see tables below). If the DIP switch is
activated for a specific function, then the parameter(s) for that function cannot be modified
by manually editing the parameter value.
114
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA

Advertisement

Table of Contents
loading

Table of Contents