Siemens SINAMICS G115D Operating Instructions Manual page 369

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Parameter
p7765
p7766[0...29
]
p7767[0...29
]
p7768[0...29
]
p7769[0...20
]
r7843[0...20] Memory card serial num‐
Further information
Preventing data reconstruction from the memory card
As soon as know-how protection has been activated, the converter only backs up encrypted
data to the memory card.
In order to guarantee know-how protection, after activating know-how protection, we
recommend that you insert a new, empty memory card. For memory cards that have already
been written to, previously backed up data that was not encrypted can be reconstructed.
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Description
KHP configuration
KHP password input
KHP password new
KHP password confirma‐
tion
KHP memory card refer‐
ence serial number
ber
Data backup and series commissioning
Setting
Configures whether the parameters and DCC data encrypted
on the memory card should be protected before using on
other memory cards or Control Units.
Bit 00: Extended copy protection - linked to the memory card
and CU
Bit 01: Basic copy protection - linked to the memory card
Bit 02: Permit trace and measuring functions for diagnostic
purposes
Sets the password for know-how protection.
Sets the new password for know-how protection.
Confirms the new password for know-how protection.
Sets the reference serial number for the memory card.
Displays the actual serial number of the memory card.
8.5 Know-how protection