Additional information on the SIMOGEAR geared motor
12.2 Specific data motor
The motors have been built using state-of-the-art technology and are shipped in an
operationally reliable condition. Changes made by users could affect this operational
reliability and are forbidden.
Note
The data on the rating plate assumes an installation altitude of up to 1 000 m above sea level.
The permissible ambient temperature is stamped on the rating plate.
In the case of other ambient temperatures and installation altitudes, contact Technical Support.
The motors have been designed for the application described in Section Technical data
(Page 439). Do not operate the motor outside the specified power limit. Other operating
conditions must be contractually agreed.
Never use degrees of protection ≤ IP54 outdoors. Air-cooled versions are designed for
ambient temperatures of ‑15 °C to +40 °C as standard and for an installation altitude of
up to 1 000 m above sea level. Please note any deviations to the data on the rating plate.
Conditions at the location of use must comply with all specifications on the rating plate.
Do not climb on the motor. Do not place any objects on the motor.
12.2.3

General technical description

The following directives and standards are relevant for the motor:
Table 12-9
Feature
Dimensioning and operational behavior
Procedure for determining the losses and the efficiency of rotating
electrical machines and tests
Measuring the energy efficiency for converter operation
Degree of protection
Cooling
Terminal marking and direction of rotation
Noise emission
Thermal protection
Starting characteristics, rotating electric motors
Efficiency classification of three-phase squirrel-cage induction motors IEC 60034‑30‑1
Energy efficiency class for converter motors (IE code)
IEC standard voltages
Safety of machinery
The motor is equipped with grease-lubricated roller bearings. The bearings are permanently
lubricated.
The stator winding is designed for temperature class 155 (F).
448
Overview of the standards
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Standard
IEC 60034‑1
IEC 60034‑2‑1
IEC 60034‑2‑2
IEC 60034‑2‑3
IEC 60034‑5
IEC 60034‑6
IEC 60034‑8
IEC 60034‑9
IEC 60034‑11
IEC 60034‑12
IEC TS 60034‑30‑2
IEC 60038
IEC 60204‑1

Advertisement

Table of Contents
loading

Table of Contents