Condensation Drain Hole (Optional); Connecting The Motor In The Terminal Box - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Additional information on the SIMOGEAR geared motor
12.2 Specific data motor
Motor
71
80
90
100
112
132
NOTICE
Collision of mounted components on the converter
With a projecting converter on Motor Mounted, care should be taken to avoid potential
collisions between the mounted components on the converter (connectors, cable entries etc.)
and neighboring components.
See mounting clearance of the converter (150 mm) in section AUTOHOTSPOT.
The permissible coolant temperature (ambient temperature at installation location) is
‑15 °C to +40 °C as standard for an installation altitude of up to 1 000 m above sea level.
Deviating data are specified on the rating plate.
Drives for ambient temperatures from ‑30 °C to +40 °C and ‑20 °C to +55 °C are available as
options.
When mounting in the vertical position with the fan cover facing upward, provide protection
to prevent foreign objects falling in, e.g. using an appropriate cover.
12.2.9

Condensation drain hole (optional)

When installing the surface-cooled motor, take care that the condensation drain holes are at the
lowest point.
12.2.10

Connecting the motor in the terminal box

For the Motor Mounted version, the converter is permanently connected to the motor. For the
connection of the converter to the electricity supply network, see previous chapters.
452
Minimum clearance of motor with G115D from wall for air intake
Motor Mounted
x in mm
150
150
150
150
150
-
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Wall Mounted
 
15
20
20
20
25
30
SINAMICS G115D Wall Mounted distributed drive