Parameter
p1076[0...n]
p1113[0...n]
p3384
p3385
p3386
p3387
p3388
p3389
p3390
p3391
p3392
p3393
p3394
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
7.9 Conveyor technology control functions (for G115D PROFINET and AS-i variants only)
Description
CI: Supplementary setpoint scaling Sets the signal source for scaling the supplementa‐
BI: Setpoint inversion
BI: Stop sensor positive direction
signal source
BI: Stop sensor negative direction
signal source
BI: Stop sensor center signal source Sets the signal source of the stop sensor for the
BI: Low speed sensor positive direc‐
tion signal source
BI: Low speed sensor negative di‐
rection signal source
BI: Low speed sensor center signal
source
BI: Stop/low speed sensor bypass
signal source
BI: Stop/low speed sensor bypass
manual operation signal source
End position shutdown activation
Conveyor technology application
selection
Stop sensor evaluation type
Advanced commissioning
Setting
ry setpoint.
Factory setting: 1
Signal source for inverting the setpoint.
1 signal: Invert setpoint
The factory setting depends on the converter field‐
bus interface.
Sets the signal source of the stop sensor for the
positive direction.
Factory setting: 0
Sets the signal source of the stop sensor for the
negative direction.
Factory setting: 0
middle position.
Factory setting: 0
Sets the signal source of the low speed sensor for
the positive direction.
Factory setting: 0
Sets the signal source of the low speed sensor for
the negative direction.
Factory setting: 0
Sets the signal source of the low speed sensor for
the middle position.
Factory setting: 0
Sets the signal source for bypassing the stop and
low speed sensors.
1 signal: The stop and low speed sensors are not
taken into account.
The factory setting depends on the converter field‐
bus interface.
Sets the signal source for bypassing the stop and
low speed sensors in the "manual operation" mode.
Factory setting: 8559.4
= 0: End position shutdown deactivated. Travel can
be continued in both directions.
= 1: End position shutdown activated (factory set‐
ting). Travel can only be continued in the opposite
direction.
Selects the conveyor technology application.
Factory setting: 0
= 1: Input signal high level triggered
= 2: Input signal low level triggered (factory setting)
= 3: Input signal 0→1 edge triggered
= 4: Input signal 1→0 edge triggered