Setpoint Processing; Overview - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Parameter
...
p1015[0...n]
p1016
p1020[0...n]
p1021[0...n]
p1022[0...n]
p1023[0...n]
r1024
r1025.0
Further information
Additional information about binary and direct selection can be found in function diagrams
3010 and 3011 in the List Manual.
7.18

Setpoint processing

7.18.1

Overview

Overview
Setpoint processing influences the setpoint using the following functions:
• "Invert" inverts the motor direction of rotation.
• The "Inhibit direction of rotation" function prevents the motor from rotating in the incorrect
direction; this function can make sense for conveyor belts, extruders, pumps and fans, for
example.
• The "Skip frequency bands" prevent the motor from being continuously operated within
these skip bands. This function avoids mechanical resonance effects by only permitting the
motor to operate briefly at specific speeds.
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Description
...
CO: Fixed speed setpoint 15 [rpm] Fixed speed setpoint 15
Fixed speed setpoint selection
mode
Fixed speed setpoint selection, bit 0 Fixed speed setpoint selection, bit 0
Fixed speed setpoint selection, bit 1 Fixed speed setpoint selection, bit 1
Fixed speed setpoint selection, bit 2 Fixed speed setpoint selection, bit 2
Fixed speed setpoint selection, bit 3 Fixed speed setpoint selection, bit 3
Fixed speed setpoint active
Fixed speed setpoint status
Advanced commissioning
7.18 Setpoint processing
Setting
...
Factory setting: 0 rpm
Fixed speed setpoint mode
Factory setting: 1
1: Direct
2: Binary
Factory setting: 0
Factory setting: 0
Factory setting: 0
Factory setting: 0
Fixed speed setpoint is active.
Fixed speed setpoint status
1 signal: Fixed speed setpoint is selected.