Siemens SINAMICS G115D Operating Instructions Manual page 151

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Status word G115D (ZSW_G115D)
Bit Meaning
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
1 = DI 0
1 = DI 1
1 = DI 2
1 = DI 3
1 = DI 24
1 = DI 25
Not used
Not used
1 = Repair switch OFF
1 = Remote control active
1 = Manual mode active
1 = Sensor bypass activated
1 = Continuous motion activated
1 = Jog left active
1 = Jog right active
Not used
7.5 Drive control via PROFINET
Description
Status of the digital input 0
Status of the digital input 1
Status of the digital input 2
Status of the digital input 3
Status of the digital input 24
Status of the digital input 25
Repair switch is set to OFF and all
power to the motor is termina‐
ted.
Remote control mode is activa‐
ted via the LRC panel.
Local control mode is activated
via the LRC panel.
Stop/low speed sensor bypass is
activated for the conveyor con‐
trol.
Continuous motion is activated
via the LRC panel.
Motor Jogs to the left.
Motor Jogs to the right.
Advanced commissioning
Signal interconnec‐
tion in the converter
p2084[0] = r0722.0
p2084[1] = r0722.1
p2084[2] = r0722.2
p2084[3] = r0722.3
p2084[4] = r0722.24
p2084[5] = r0722.25
p2084[8] = r8559.12
p2084[9] = r8559.2
p2084[10] = r8559.3
p2084[11] = r8559.4
p2084[12] = r8559.5
p2084[13] = r8559.6
p2084[14] = r8559.7
149