Siemens SINAMICS G115D Operating Instructions Manual page 169

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

No.
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
Siemens Motor Data Object, Instance Number: 32D hex
Supported services
Class
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Type
Service Name
REAL
get
Actual Current
REAL
get
Actual Torque
REAL
get
Output power
REAL
get
Motor Temperature
REAL
get
Power Unit Temperature r0037[0]   power unit temperature
REAL
get
Energy kWh
UINT8
get
CDS Eff (Local Mode)
WORD
get
Status Word 2
WORD
get
Control Word 1
REAL
get
Motor Speed (Encoder)
UINT32
get
Digital Inputs
UINT32
get
Digital Outputs
REAL
get
Analog Input 1
REAL
get
Analog Input 2
REAL
get
Analog Output 1
REAL
get
Analog Output 2
UINT16
get
Fault Code 1
UINT16
get
Fault Code 2
UINT16
get
Fault Code 3
UINT16
get
Fault Code 4
UINT16
get
Fault Code 5
UINT16
get
Fault Code 6
UINT16
get
Fault Code 7
UINT16
get
Fault Code 8
REAL
get
Pulse Frequency
UINT16
get
Alarm Code 1
UINT16
get
Alarm Code 2
UINT16
get
Alarm Code 3
UINT16
get
Alarm Code 4
REAL
get
PID setpoint Output
REAL
get
PID Feedback
REAL
get
PID Output
• Get Attribute single
Advanced commissioning
7.6 Drive control via Ethernet/IP
Value/explanation
r0027   current actual value
r0031   torque actual value
r0032   actual active power value
r0035[0]   motor temperature
r0039   energy display
r0050   active command data set
r0053   status word 2
r0054   control word 1
r0061   speed actual value
r0722   digital inputs status
r0747   digital outputs status
r0752[0]   analog input 1
r0752[1]   analog input 2
r0774[0]   analog output 1
r0774[1]   analog output 2
r0947[0]   fault number 1
r0947[1]   fault number 2
r0947[2]   fault number 3
r0947[3]   fault number 4
r0947[4]   fault number 5
r0947[5]   fault number 6
r0947[6]   fault number 7
r0947[7]   fault number 8
r1801   pulse frequency
r2110[0]   alarm number 1
r2110[1]   alarm number 2
r2110[2]   alarm number 3
r2110[3]   alarm number 4
r2260 technology controller setpoint after the
ramp-function generator
r2266 technology controller actual value after
the filter
r2294   technology controller output signal
Instance
• Get Attribute single
• Set Attribute single
167

Advertisement

Table of Contents
loading

Table of Contents