Advanced commissioning
7.6 Drive control via Ethernet/IP
No.
4
5
6
10
Parameter Object,    Instance Number: 401 hex
Supported services
Class
170
Service
Type
Name
get_and
Struct of Interface Counters
_clear
UINT32 In Octets
UINT32 In Ucast Packets
UINT32 In NUcast Packets
UINT32 In Discards
UINT32 In Errors
UINT32 In Unknown Protos
UINT32 Out Octets
UINT32 Out Ucast Packets
UINT32 Out NUcast packets
UINT32 Out Discards
UINT32 Out Errors
get_and
Struct of Media Counters
_clear
UINT32 Alignment Errors
UINT32 FCS Errors
UINT32 Single Collisions
UINT32 Multiple Collisions
UINT32 SQE Test Errors
UINT32 Deferred Transmis‐
sions
UINT32 Late Collisions
UINT32 Excessive Collisions
UINT32 MAC Transmit Errors
UINT32 Carrier Sense Errors
UINT32 Frame Too Long
UINT32 MAC Receive Errors
get, set
Struct of Interface Control
UINT16 Control Bits
UINT16 Forced Interface
Speed
get
String
Interface_Label
• Get Attribute all
Value/explanation
Optional, required if the "Media Counters Attribute" is
implemented.
Received octets
Received Unicast packets
Received non-Unicast packets
Incoming packets, not processed
Incoming packets with errors
Incoming packets with unknown protocol
Sent octets
Sent Unicast packets
Sent non-Unicast packets
Outgoing packets, not processed
Outgoing packets, with errors
Media-specific counters
Structure received, which does not match the num‐
ber of octets
Structure received, which does not pass the FCS check
Structure successfully transmitted, precisely one col‐
lision
Structure successfully transmitted, several collisions
Number of SQE errors
First transmission attempt delayed
Number of collisions that occurred delayed by 512 bit
timers to the request
Transmission unsuccessful as a result of intensive col‐
lisions
Transmission unsuccessful as a result of an internal
MAC sublayer transmission error.
Times that the carrier sense condition was lost or
never asserted when attempting to transmit a frame
Structure too large
Transmission unsuccessful as a result of an internal
MAC sublayer receive error.
 
 
 
Interface-Label
Instance
• Get Attribute all
• Set Attribute single