If you are using a Siemens motor, then the converter automatically selects the appropriate
technique to determine the pole position.
Each time the motor is switched on (ON/OFF1 command), the converter identifies the pole
position.
Figure 7-10
As a result of the pole position identification, the motor responds to an ON command with
a delay of up to 1 second. The motor shaft can rotate slightly during the pole position
identification.
Parameters
Parameters
p1980
r1992
p1998[D]
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Pole position identification after switching on the motor
Description
PolID technique
CO/BO: PolID diagnostics
PolID circle center point
Advanced commissioning
7.20 Motor control
Factory setting
4
-
0.0 [A]
307