Checking The Oil Level Prior To Commissioning; Mounting The Oil Expansion Tank - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Additional information on the SIMOGEAR geared motor
12.3 Specific data gearbox
12.3.20

Checking the oil level prior to commissioning

Check the oil level before commissioning. If necessary, correct the oil level.
Siemens recommends a complete oil change after a storage time longer than 24 months:
• For gearboxes with long-term preservation.
• For gearboxes supplied completely filled with oil.
Follow Checking and changing lubricants (Page 514).
Gearbox in special mounting position
The gearbox is intended for a specific rotation angle and is delivered with the correct quantity
of oil for this purpose.
It is not possible to check the oil level. You will find information regarding oil quantity and
type of oil on the rating plate.
12.3.21

Mounting the oil expansion tank

An oil expansion unit can be used depending on the power, input speed, mounting position and
transmission ratio. The oil expansion unit is used to equalize changes in the oil volume caused
by temperature fluctuations in operation.
Before commissioning the gearbox, replace the screw plug with the oil expansion unit.
Oil expansion unit size 39 - 89
The unit is supplied as a mounting kit, and can be attached to the geared motor vertically or
at an angle.
508
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA

Advertisement

Table of Contents
loading