Use As Prescribed; General Technical Description - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Additional information on the SIMOGEAR geared motor
11.2 Specific data motor
11.2.2

Use as prescribed

The motors described in these operating instructions have been designed for stationary use in
general engineering applications.
They comply with the harmonized standards of the series EN 60034 (VDE 0530). They are not
approved for operation in hazardous zones and areas.
Unless otherwise agreed, the motors have been designed for use in plants and equipment in
industrial environments.
The motors have been built using state-of-the-art technology and are shipped in an
operationally reliable condition. Changes made by users could affect this operational
reliability and are forbidden.
Note
The data on the rating plate assumes an installation altitude of up to 1 000 m above sea level.
The permissible ambient temperature is stamped on the rating plate.
In the case of other ambient temperatures and installation altitudes, contact Technical
Support.
The motors have been designed for the application described in Section Technical data
(Page 397). Do not operate the motor outside the specified power limit. Other operating
conditions must be contractually agreed.
Never use degrees of protection ≤ IP54 outdoors. Air-cooled versions are designed for
ambient temperatures of -15 °C to +40 °C as standard and for an installation altitude of up to
1 000 m above sea level. Please note any deviations to the data on the rating plate.
Conditions at the location of use must comply with all specifications on the rating plate.
Do not climb on the motor. Do not place any objects on the motor.
11.2.3

General technical description

The motor complies with the following regulations:
Table 11- 10 Overview of the standards
Feature
Dimensioning and operational behavior
Degree of protection
Cooling
Mounting position according to modular system
Terminal marking and direction of rotation
Noise emission
Thermal protection
Starting characteristics, rotating electric motors
Vibration severity levels
IEC standard voltages
Safety of machinery
406
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
Standard
EN 60034-1
EN 60034-5
EN 60034-6
EN 60034-7
EN 60034-8
EN 60034-9
EN 60034-11
EN 60034-12
EN 60034-14
IEC 60038
EN 60204-1
SINAMICS G115D distributed drive

Advertisement

Table of Contents
loading

Table of Contents