SINAMICS S120 at Technology CPU Entry ID: 21767896
2.
3.
4.
You can now perform this test also for the second drive of the SINAMICS
S120 training case and thus check the functionality of your configuration.
7.2

Control via the technology CPU

The control of SINAMICS S120 via the technology CPU is performed via
the respective technology objects of the technology CPU.
Note
For further information on the configuration and use of the technology
objects of an axis, please refer to the application examples on the
technology CPU which are available on the internet (see appendix:
Internet links).
7.2.1

Creating an axis in S7T Config

The respective drive of SINAMICS S120 has to be created as axis in the
S7T Config configuration tool of the technology CPU. The respective
settings are made for this axis and assigned to the desired drive of
SINAMICS S120.
V1.0
Commissioning SINAMICS S120
Set the desired speed in the input
box.
The motor should now start moving
at the set speed.
Stop the drive by clicking the red
OFF button.
Return the control priority to the
higher-level controller by clicking
the Return button and acknowledge
the query with Yes.