change system-parameters maintenance
Table 8-1. Scheduled Maintenance Settings — Continued
DSO
Loop-Around
Test Call
Extension
SPE Optional
Boards
Output (page 2)
The following example shows the output from page 2 of the change
system-parameters maintenance command.
555-233-123
The extension used to set up a DSO loop around connection for
testing non-ISDN DS1 trunks. The DSO Loop-Around Test Call
feature is used primarily for testing DSO channels associated with
non ISDN-PRI trunks. The loop-around is activated by dialing the
test extension number; multiple DSO Loop-Around connections
can be established by placing multiple calls to the loop-around
extension.
For more information see
Maintenance
Procedures''.
These fields indicate if a Disk circuit pack is present, and identifies
administered Packet Interface slots. If a Packet Interface circuit
pack is present, the corresponding Packet Interface field is set to y
when the system boots. No change to that field is allowed. If the
system is equipped with duplicated SPEs, the
field is set to y if either SPE carrier contains a Packet
Interface
Interface circuit pack in the corresponding position. If a Packet
Interface circuit pack is not present, the value for the
field is read from translation data, and stored on disk
Interface
or tape. If the field is set to n, a Packet Interface circuit pack may
be administered by changing the corresponding
Interface
field to y.
''Facility test calls''
in
Chapter 5, ''Routine
Packet
Packet
Continued on next page
Issue 4 May 2002
Packet
8-41