Maintenance Commands and Trouble-Clearing Aids
System resets, that are less severe than a reboot, rarely affect the error and alarm
logs.
NOTE:
If the error and alarm logs contain SYSTEM errors, then use display
initcauses to search for information that the system could not log during
reset operation.
Action/
Object
Qualifier
display
print
alarms
schedule
1
Refer to the Report Scheduler and System Printer feature specification for more details.
Feature Interactions
If the user disables the alarm origination with the change system
parameters-maintenance command, then the Ack? (Acknowledged) field
on the Alarm Report is blank regardless of the true acknowledged state of
the alarm.
Options screen
Use display alarms to show the options screen, and select the options you want
to view on the report. The figure below is an example of the options screen for
Alarm Reports.
8-54
Issue 4 May 2002
Qualifier Description
Report sent to printer
Command is validated and
then a scheduling form
displays to schedule
execution of the command.
The command is then placed
in the command queue and is
executed at the specified
time. The information
displayed by the command is
sent to the system printer
1
instead of the screen.
Examples:
display alarms
display alarms print
display alarms schedule
Logins
Defaults
init
all alarms
inads
displayed
craft
cust
rcust
bcms
browse
Feature
Interactions
see below