Avaya Definity SI Maintenance Manual page 293

Table of Contents

Advertisement

change system-parameters maintenance
Output (page 3)
change system-parameters maintenance
MAINTENANCE-RELATED SYSTEM PARAMETERS
Modem Connection: external
Modem Name: _______
RTS/CTS Enabled: \Q3
S0=10
Asynchronous Data Mode: &M0&Q0
Type: T
DTE Auto-Data Speed: ______
Ratio:
Disable Data Compression: ______
Command: D
Enable Error Control: ______
Time-out: S7=255
Misc. Init. Param: ______________
Field descriptions (page 3)
Modem Connection
On page 3 of the example forms, 11 fields disappear when the Modem
Connection? field is set to internal. In this example the Modem Connection
field is set to external, revealing the 11 fields.
The first 2 fields on page 3 help setup the data format for the serial data from the
switch to the modem.These fields are display-only, and they must contain the
following values:
Data Bits = 8, Parity = None
The remaining fields are listed below.
Modem
Connection
Modem Name
RTS/CTS
Enabled
555-233-123
Data Bits: 8
Parity: none
Valid entries are
This field is 20 characters long and will permit alpha-numeric
characters to provide a unique qualifier for a given modem. ()
This field will inform the modem that communication with the
data source UART will be driven with RTS/CTS flow control.
This field is 6 characters long and is case in-sensitive. (\Q3)
Page 3 of 3
Auto Answer Ring Count (rings):
Adjustable Make/Break
No Answer
internal
or
external
Issue 4 May 2002
Dial
Dial
.
8-43

Advertisement

Table of Contents
loading

Table of Contents