SERVICE MANUAL NUMBER 28
4. Immerse Electrode Tester in the water within 6 in. (150 mm) of aft end of sterndrive unit.
IMPORTANT: There will be different voltage readings depending on the type of Mer-
Cathode System you are testing.
5. The following readings indicate that the sterndrive unit is adequately protected:
6. If the reading is not within specified limits, or if reading is within specifications but there
90-863160 MAY 2000
Electrode Mounted on Bottom of Transom Assembly
Electrodes Mounted on Boat Transom
a. MODELS WITH ELECTRODES MOUNTED ON BOAT TRANSOM
Fresh Water Areas -
7.5 - 10.5 millivolts with Quicksilver
VOA Meter
750 - 1050 Millivolts with Digital Meter
Salt, Polluted or Mineral Laden Water Areas:
8.8 - 10.5 millivolts with Quicksilver
VOA Meter
880 - 1050 Millivolts with Digital Meter
b. MODELS WITH ELECTRODE MOUNTED ON BOTTOM OF TRANSOM ASSEMBLY
Fresh Water Areas -
6.2 - 11.8 Millivolts with Quicksilver
VOA Meter
620 - 1180 Millivolts with Digital Meter
Salt, Polluted or Mineral Laden Water Areas:
7.5 - 11.8 Millivolts with Quicksilver
VOA Meter
750 - 1180 Millivolts with Digital Meter
is evidence of corrosion on sterndrive, refer to the following troubleshooting charts to
aid in diagnosis.
CORROSION PROTECTION - ALL MODELS