SERVICE MANUAL NUMBER 28
IN/DOWN OPERATION
1. Connect a jumper wire between the positive (+) solenoid terminal and the green-white
2. The motor should run.
3. If the motor does not run, refer to "Motor Repair."
90-863160 MAY 2000
motor lead terminal.
d
a -
IN/DOWN Solenoid
b -
Positive Terminal (+)
c -
GREEN-WHITE Motor Lead Terminal
d -
Jumper Wire
b
a
c
OILDYNE TRIM PUMP
73556
Page 5A-17