OILDYNE TRIM PUMP
3. Connect the ohmmeter between the field brush lead and the GREEN/WHITE lead.
4. Zero ohms indicated (full continuity) - Field OK.

Test for Short in Field

1. Connect the ohmmeter between the field brush lead and the field frame.
2. Zero ohms indicated (full continuity) - Short indicated (replace field assembly).
Page 5A-44
b
a -
Ohmmeter Lead - Connected to Brush Lead
b -
Ohmmeter Lead - Connected to GREEN/WHITE Lead
Zero ohms not indicated (no continuity) - Replace field assembly.
b
a -
Field Frame
b -
Field Brush Lead
Zero ohms not indicated (no continuity) - Field OK.
a