SERVICE MANUAL NUMBER 28
Drive Shaft Housing and Gear Housing Separation
1. Remove, empty and clean gear lube monitor.
2. Tilt drive unit to a 45° angle. Remove fill/drain screw and drive shaft housing vent screw.
3. Remove gear housing from drive shaft housing.
4. Finish draining gear case by turning upside down over a container.
90-863160 MAY 2000
Allow drive unit to drain completely.
a -
Fill/Drain Screw
a -
Nuts And Washers (6)
b -
Bolt (1)
a
b
BRAVO TWO GEAR HOUSING
a
76801