SERVICE MANUAL NUMBER 28
3. Clean bellows mounting flange on gimbal housing with sandpaper and wipe clean with
Be sure to read and follow package label direction when using bellows adhesive.
4. Apply bellows adhesive to inside diameter of bellows end that will be attached to gimbal
IMPORTANT: TOP mark on U-joint bellows must be facing upward when installing
bellows.
90-863160 MAY 2000
lacquer thinner.
a -
Mounting Flange
housing. Bellows adhesive IS NOT needed on the other end that connects to the bell
housing. Allow to dry until adhesive is no longer tacky (approximately 10 minutes) before
installing.
a -
Inside Diameter of Bellows End
a -
TOP Mark
b -
Bead
SERVICE PROCEDURES REQUIRING MAJOR DISASSEMBLY
a
WARNING
b
a
a
Page 4B-27
76662
50383
50383