SERVICE MANUAL NUMBER 28
2. Connect the gauge at the most convenient location.
3. Open valves "A" and "B" and the run pump OUT/UP and IN/DOWN several times to
4. Run the pump OUT/UP until the trim cylinders are fully extended.
5. Observe the gauge while pumping. The pressure should be 2200-2600 psi
90-863160 MAY 2000
d
Gauge Connected to Pump
a -
Hydraulic Test Gauge
b -
Hose Connected to UP (Left Hole)
c -
Fittings - (Supplied with Gauge)
d -
BLACK Hose (From Gimbal Housing)
e -
GREY Hose (From Gimbal Housing)
c
Gauge Connected to Hydraulic Connector
a -
Test Gauge
b -
Coupling (Supplied with Gauge)
c -
Front Hydraulic Connector Port
purge air.
(15173-17932 kPa).
b
c
a
A
B
b
OILDYNE TRIM PUMP
e
a
70598
50390
Page 5A-13